40,000 L/H Stainless Steel RO Water Treatment System for Industrial Applications
Product Overview
This reverse osmosis (RO) water treatment system is designed for industrial process water preparation, with a nominal capacity of 40,000 liters per hour. Actual output depends on feedwater quality, water temperature, operating pressure, and system configuration.
The system combines pretreatment filtration with RO membrane separation to reduce dissolved salts and selected dissolved substances in the feedwater. Its stainless steel frame and open layout provide access for inspection, routine maintenance, and component servicing.
Working Principle
Reverse osmosis uses pressure to move water through a semi-permeable membrane. The feedwater is separated into two streams: permeate, which passes through the membrane, and concentrate, which carries the retained substances out of the system.
Pretreatment helps condition the feedwater before it enters the RO membranes. The filtration arrangement and membrane selection are determined according to the source water analysis and the required product water quality.
Feedwater Requirements
For the configuration described, feedwater TDS should be below 500 mg/L.
Additional feedwater parameters should be reviewed before system selection, including hardness, turbidity, pH, temperature, and residual chlorine. Pretreatment requirements depend on the complete water analysis.
Main Features
Nominal capacity of 40,000 L/H under specified design conditions.
Stainless steel frame for equipment support and installation.
Pretreatment filtration before RO membrane processing.
Double-pass RO configuration for applications requiring further reduction of dissolved salts.
Automatic operation through the configured control system.
Accessible layout for routine inspection and maintenance.
Typical Process Flow
Raw Water Collection → Raw Water Tank → Feed Pump → Quartz Sand Filter → Activated Carbon Filter → Cartridge Filtration → First-Pass High-Pressure Pump → First-Pass RO Membranes → Intermediate Water Tank → Second-Pass High-Pressure Pump → Second-Pass RO Membranes → Product Water Tank → Transfer Pump → Production Area
The final process arrangement and filtration stages are subject to the confirmed equipment configuration.
Double-Pass RO Configuration
In a double-pass RO system, permeate from the first pass becomes the feedwater for the second pass. This additional membrane treatment can further reduce residual dissolved salts and support applications with more demanding process water requirements.
Energy consumption, water recovery, and operating costs depend on the system design and operating conditions. These parameters should be evaluated for each project.
Typical Applications
The system can be integrated into process water preparation systems for:
Food and beverage production.
Industrial manufacturing.
Chemical processing.
Electronics production.
Centralized commercial water treatment.
Suitability for a specific application depends on the required water specifications, any additional treatment steps, and verification of the final water quality.
Project Configuration
System selection is based on source water analysis, required output, product water specifications, installation conditions, and operating requirements.
| Output | 40000L PER HOUR |
| Material | SUS304 |
| Custom made | YES |
| Pipeline | SUS304 and PVC |
| Ro Stage | 2 stage |
| High Pressure Pump | Grundfos/ CNP |
| Warranty | 1.5 years |
![]()
![]()
![]()
![]()
![]()
|
| Brand Name: | Waterpro /OEM |
| Model Number: | RO-40000LPH |
| MOQ: | 1 |
| Packaging Details: | Naked or export wooden case |
| Payment Terms: | L/C, D/A, T/T, Western Union |
40,000 L/H Stainless Steel RO Water Treatment System for Industrial Applications
Product Overview
This reverse osmosis (RO) water treatment system is designed for industrial process water preparation, with a nominal capacity of 40,000 liters per hour. Actual output depends on feedwater quality, water temperature, operating pressure, and system configuration.
The system combines pretreatment filtration with RO membrane separation to reduce dissolved salts and selected dissolved substances in the feedwater. Its stainless steel frame and open layout provide access for inspection, routine maintenance, and component servicing.
Working Principle
Reverse osmosis uses pressure to move water through a semi-permeable membrane. The feedwater is separated into two streams: permeate, which passes through the membrane, and concentrate, which carries the retained substances out of the system.
Pretreatment helps condition the feedwater before it enters the RO membranes. The filtration arrangement and membrane selection are determined according to the source water analysis and the required product water quality.
Feedwater Requirements
For the configuration described, feedwater TDS should be below 500 mg/L.
Additional feedwater parameters should be reviewed before system selection, including hardness, turbidity, pH, temperature, and residual chlorine. Pretreatment requirements depend on the complete water analysis.
Main Features
Nominal capacity of 40,000 L/H under specified design conditions.
Stainless steel frame for equipment support and installation.
Pretreatment filtration before RO membrane processing.
Double-pass RO configuration for applications requiring further reduction of dissolved salts.
Automatic operation through the configured control system.
Accessible layout for routine inspection and maintenance.
Typical Process Flow
Raw Water Collection → Raw Water Tank → Feed Pump → Quartz Sand Filter → Activated Carbon Filter → Cartridge Filtration → First-Pass High-Pressure Pump → First-Pass RO Membranes → Intermediate Water Tank → Second-Pass High-Pressure Pump → Second-Pass RO Membranes → Product Water Tank → Transfer Pump → Production Area
The final process arrangement and filtration stages are subject to the confirmed equipment configuration.
Double-Pass RO Configuration
In a double-pass RO system, permeate from the first pass becomes the feedwater for the second pass. This additional membrane treatment can further reduce residual dissolved salts and support applications with more demanding process water requirements.
Energy consumption, water recovery, and operating costs depend on the system design and operating conditions. These parameters should be evaluated for each project.
Typical Applications
The system can be integrated into process water preparation systems for:
Food and beverage production.
Industrial manufacturing.
Chemical processing.
Electronics production.
Centralized commercial water treatment.
Suitability for a specific application depends on the required water specifications, any additional treatment steps, and verification of the final water quality.
Project Configuration
System selection is based on source water analysis, required output, product water specifications, installation conditions, and operating requirements.
| Output | 40000L PER HOUR |
| Material | SUS304 |
| Custom made | YES |
| Pipeline | SUS304 and PVC |
| Ro Stage | 2 stage |
| High Pressure Pump | Grundfos/ CNP |
| Warranty | 1.5 years |
![]()
![]()
![]()
![]()
![]()