Send Message
Good price online

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Ro Water Treatment Plant
Created with Pixso. Reverse Osmosis Ro Water Treatment Plant 500LPH With FRP Tank

Reverse Osmosis Ro Water Treatment Plant 500LPH With FRP Tank

Brand Name: Waterpro /OEM
Model Number: RO-500LPH
MOQ: 1
Price: USD1170 -USD2400
Delivery Time: 35 work days
Payment Terms: L/C, D/A, T/T, Western Union
Detail Information
Place of Origin:
China
Certification:
CE
Material:
Stainless Steel, FRP Tank
Usage:
Reclaimed Water Plant Rainwater Recovery Station After Water Plant Sewage Treatment Plant
Capacity:
500LPH
Votalge:
380V 50Hz, Or Customerized
After Warranty Service:
Video Technical Support, Online Support
Raw Water TDS:
<2000PPM
Pure Water TDS:
<10PPM
Warranty:
One Year
Packaging Details:
Naked or export wooden case
Supply Ability:
30 PCS per month
Highlight:

Reverse Osmosis Ro Water Treatment Plant

,

Ro Water Treatment Plant 500LPH

,

FRP 500 lph ro water plant

Product Description

Reverse Osmosis Ro Water Treatment Plant 500LPH With FRP Tank

 

RO reverse osmosis system

Reverse osmosis water treatment equipment uses pretreatment device (quartz sand filter, activated carbon, water softener, security filter) With RO reverse osmosis system multiple filtration and separation of water ion technology, the salt removal rate can reach 97%-99%
 
Working Process Chart:
Raw water pump→ Quartz sand filter→ activated carbon filter→ Water softener→security filter → high pressure pump→Reverse osmosis system→UV/Ozone→ pure water tank
 
Function of every part:
1. Raw water pump-- provide the pressure to quartz sand filter/active carbon filter/ water softener
2. Sand filter-- get rid of turbidity, suspended matter
3. Active Carbon filter--Remove the color, free chloride, organic matter, harmful matter, ect.
4. Softener--exchange "ions" of calcium and magnesium with the most common and easiest method.
5. Security filter--prevent large particles into RO membrane, accuracy is 5um,
6. High pressure pump-- Provide the high pressure to RO membrane
7. RO system-- main part of the plant. The RO membrane's desalting rate can reach 97% and above, removing over 99% ions.
Mode
RO-500L
Production capacity
500L/H
Power
About 1.47KW
RO membrane
Toray RO membrane 4040
Voltage
110V-480V/1ph/3ph/50Hz/60hz (could be change)
Desalination rate
97% - 99%
Recovery rate
50%-75%
Material
FRP,SUS304,PVC,
Certificate
CE&ISO9001
Warranty
One year

 

 

Every part of the reverse osmosis system

S/N.
Commodity name
Application
 
1
Raw water tank
Store water, buffering pressure, overcome instability of supplying water by pipe, ensure to supply water stably and continuously
for whole system. (Customer provide for themselves, because big size will result in expensive freight.)
2
Raw water pump or called booster pump
Provide needed pressure for every pretreatment filter
 
3
Mechanical filter or called quartz sand filter or sand filter
We use fiber glass or stainless steel vessel as housing, fill quarts sand, it can filter big particles impurities, suspended
substances, colloids etc.
 
4
Activated carbon filter
We use fiber glass or stainless steel vessel as housing, fill activated carbon, remove color, odor, residual chlorine and organics
substances.
 
5
Water softener, demineralizer, or called Na+ exchanger;chemical dosing system(optional)
Adopt cation resin to soften water, cation resin will absorb Ca2+, Mg2+(main elements for composing scale), reduce hardness of raw water, System can make resin intelligently regenerate, recycling
6
Security filter or pp filter, or called PP sediment filter
prevent large particles, bacteria, viruses into RO membrane, accuracy is 5µm,
 
7
High pressure pump
Provide needed working pressure for RO system, ensure production capacity of pure water. (CNP pump or custom other brand)
 
8
RO(reverse osmosis) system
Can remove particles, colloids, organic impurities, heavy metal ions, bacteria, virus, heat source etc. harmful substances and 99%
dissolved salts. (RO membranes USA Filmtec)

 

Reverse Osmosis Ro Water Treatment Plant 500LPH With FRP Tank 0

Reverse Osmosis Ro Water Treatment Plant 500LPH With FRP Tank 1

Reverse Osmosis Ro Water Treatment Plant 500LPH With FRP Tank 2

Good price online

Products Details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Ro Water Treatment Plant
Created with Pixso. Reverse Osmosis Ro Water Treatment Plant 500LPH With FRP Tank

Reverse Osmosis Ro Water Treatment Plant 500LPH With FRP Tank

Brand Name: Waterpro /OEM
Model Number: RO-500LPH
MOQ: 1
Price: USD1170 -USD2400
Packaging Details: Naked or export wooden case
Payment Terms: L/C, D/A, T/T, Western Union
Detail Information
Place of Origin:
China
Brand Name:
Waterpro /OEM
Certification:
CE
Model Number:
RO-500LPH
Material:
Stainless Steel, FRP Tank
Usage:
Reclaimed Water Plant Rainwater Recovery Station After Water Plant Sewage Treatment Plant
Capacity:
500LPH
Votalge:
380V 50Hz, Or Customerized
After Warranty Service:
Video Technical Support, Online Support
Raw Water TDS:
<2000PPM
Pure Water TDS:
<10PPM
Warranty:
One Year
Minimum Order Quantity:
1
Price:
USD1170 -USD2400
Packaging Details:
Naked or export wooden case
Delivery Time:
35 work days
Payment Terms:
L/C, D/A, T/T, Western Union
Supply Ability:
30 PCS per month
Highlight:

Reverse Osmosis Ro Water Treatment Plant

,

Ro Water Treatment Plant 500LPH

,

FRP 500 lph ro water plant

Product Description

Reverse Osmosis Ro Water Treatment Plant 500LPH With FRP Tank

 

RO reverse osmosis system

Reverse osmosis water treatment equipment uses pretreatment device (quartz sand filter, activated carbon, water softener, security filter) With RO reverse osmosis system multiple filtration and separation of water ion technology, the salt removal rate can reach 97%-99%
 
Working Process Chart:
Raw water pump→ Quartz sand filter→ activated carbon filter→ Water softener→security filter → high pressure pump→Reverse osmosis system→UV/Ozone→ pure water tank
 
Function of every part:
1. Raw water pump-- provide the pressure to quartz sand filter/active carbon filter/ water softener
2. Sand filter-- get rid of turbidity, suspended matter
3. Active Carbon filter--Remove the color, free chloride, organic matter, harmful matter, ect.
4. Softener--exchange "ions" of calcium and magnesium with the most common and easiest method.
5. Security filter--prevent large particles into RO membrane, accuracy is 5um,
6. High pressure pump-- Provide the high pressure to RO membrane
7. RO system-- main part of the plant. The RO membrane's desalting rate can reach 97% and above, removing over 99% ions.
Mode
RO-500L
Production capacity
500L/H
Power
About 1.47KW
RO membrane
Toray RO membrane 4040
Voltage
110V-480V/1ph/3ph/50Hz/60hz (could be change)
Desalination rate
97% - 99%
Recovery rate
50%-75%
Material
FRP,SUS304,PVC,
Certificate
CE&ISO9001
Warranty
One year

 

 

Every part of the reverse osmosis system

S/N.
Commodity name
Application
 
1
Raw water tank
Store water, buffering pressure, overcome instability of supplying water by pipe, ensure to supply water stably and continuously
for whole system. (Customer provide for themselves, because big size will result in expensive freight.)
2
Raw water pump or called booster pump
Provide needed pressure for every pretreatment filter
 
3
Mechanical filter or called quartz sand filter or sand filter
We use fiber glass or stainless steel vessel as housing, fill quarts sand, it can filter big particles impurities, suspended
substances, colloids etc.
 
4
Activated carbon filter
We use fiber glass or stainless steel vessel as housing, fill activated carbon, remove color, odor, residual chlorine and organics
substances.
 
5
Water softener, demineralizer, or called Na+ exchanger;chemical dosing system(optional)
Adopt cation resin to soften water, cation resin will absorb Ca2+, Mg2+(main elements for composing scale), reduce hardness of raw water, System can make resin intelligently regenerate, recycling
6
Security filter or pp filter, or called PP sediment filter
prevent large particles, bacteria, viruses into RO membrane, accuracy is 5µm,
 
7
High pressure pump
Provide needed working pressure for RO system, ensure production capacity of pure water. (CNP pump or custom other brand)
 
8
RO(reverse osmosis) system
Can remove particles, colloids, organic impurities, heavy metal ions, bacteria, virus, heat source etc. harmful substances and 99%
dissolved salts. (RO membranes USA Filmtec)

 

Reverse Osmosis Ro Water Treatment Plant 500LPH With FRP Tank 0

Reverse Osmosis Ro Water Treatment Plant 500LPH With FRP Tank 1

Reverse Osmosis Ro Water Treatment Plant 500LPH With FRP Tank 2