Industry Electrolysis RO Brackish Water Treatment Plant

Basic Information
Place of Origin: China
Brand Name: XST
Certification: ISO9001
Minimum Order Quantity: 1 Unit
Price: USD 9000 Per Unit
Packaging Details: Wooden Case
Delivery Time: 10-20 work day
Payment Terms: T/T
Supply Ability: 50 Units Per Month
Output Flow: 100-15000GPM Materials: FRP, UPVC, S.S304/316
Operation: Automatic Control TDS: >2000ppm
Turbidity: <100NTU Local Electricity: 220V / 380V / 415V - 50Hz/60Hz
Feed Water: Tap Water, Well Water, Underground Water, Brackish Water... Membranes: Dow / Toray/ CSM/ Hydraunics/ Vontron Etc As Clients' Requirement
Rejected Rate: ≥99% Temperature: 4~45℃
Service Provided: Online Support,commissioning And Training,Field Installation,Video Technical Support,Field Maintenance And Repair Service Certification: ISO9001, CE
High Light:

RO Brackish Water Treatment Plant

,

UPVC Brackish Water Treatment Plant

,

10000GPM Water Purification System

Large Capacity Industry Electrolysis RO Reverse Osmosis Water Purification System

Product Description

 

Description of RO Brackish Water Treatment Plant

Reverse osmosis is a water purification technology that uses a semipermeable membrane to remove larger particles from drinking water. It differs from filtration in that the mechanism of fluid flow is by osmosis across a membrane. The predominant removal mechanism in membrane filtration is straining, or size exclusion, where the pores are 0.01 micrometers or larger, so the process can theoretically achieve perfect efficiency regardless of parameters such as the solution's pressure and concentration. Reverse osmosis instead involves solvent diffusion across a membrane that is either nonporous or uses nanofiltration with pores 0.001 micrometers in size. The predominant removal mechanism is from differences in solubility or diffusivity, and the process is dependent on pressure, solute concentration, and other conditions.[2] Reverse osmosis is most commonly known for its use in drinking water purification from seawater, removing the salt and other effluent materials from the water molecules

The Brackish Water Treatment System is belong to Reverse osmosis (RO) system, which the inlet water quality is a little worse, which the TDS may be more than 2000mg/L, and it needs the higher standard of materials when we make the design.

 

Industry Electrolysis RO Brackish Water Treatment Plant 0

 

Flowchart and Views

 

Main Process of RO Brackish Water Treatment Plant


1. feed water pump pump-- provide the pressure to quartz sand filter/active carbon filter
2. Multi-medium filter-- get rid of turbidity, suspended matter, organic matter, colloid, ect.
3. Active Carbon filter--Remove the color, free chloride, organic matter, harmful matter, ect.
4. Softener--exchange "ions" of calcium and magnesium with the most common and easiest method.
5. Security filter--prevent large particles, bacteria, viruses into RO membrane, accuracy is 5um
6. High pressure pump-- Provide the high pressure to RO membrane
7.Brackish water treatment system-- main part of the plant. The RO membrane's desalting rate can reach 99%, removing over 99% ions

 

Model Capability Operation Feed inlet Membrane Membrane Recovery Power
(Tons/Hr) (MPa) (MM) Size(Inch) (Qty) (KW)
XSTBWRO-1 1 1.0-1.4 DN25 40×40 6 60% 3
XSTBWRO-2 2 1.0-1.4 DN25 40×40 10 60% 4.5
XSTBWRO-3 3 1.0-1.4 DN32 40×40 14 60% 5
XSTBWRO-6 6 1.0-1.4 DN40 80×40 14 60% 7.5
XSTBWRO-10 10 1.0-1.4 DN50 80×40 12 60% 15
XSTBWRO-15 15 1.0-1.4 DN50 80×40 18 60% 20
XSTBWRO-20 20 1.0-1.4 DN65 80×40 22 60% 32

 

Pictures of RO Brackish Water Treatment Plant

 

Industry Electrolysis RO Brackish Water Treatment Plant 1Industry Electrolysis RO Brackish Water Treatment Plant 2Industry Electrolysis RO Brackish Water Treatment Plant 3

Assessories and Details

 

Industry Electrolysis RO Brackish Water Treatment Plant 4Industry Electrolysis RO Brackish Water Treatment Plant 5

Industry Electrolysis RO Brackish Water Treatment Plant 6

Equipment Maintenance

 

Maintenance of RO Brackish Water Treatment Plant

 

Replacement time of consumable parts

There are several kinds of consumables you need to replace regularly.

a. Quartz sand: replaced about every 15-18 months. 50kg/bag

b. Activated carbon: replaced about every 15-18 months. 25kg/bag

c. Resin: replaced about every 15 months. 25L/bag

d. PP Filter cartridge: replaced about every 3 month

e. RO membrane: replaced about every 2years

We suggest customers buy 1- 2 years of PP filter cartridges together with machine. Because these PP filter cartridges need to be replaced every month.

 

Packing and Shipping

Industry Electrolysis RO Brackish Water Treatment Plant 7Industry Electrolysis RO Brackish Water Treatment Plant 8

 

Other Products

Industry Electrolysis RO Brackish Water Treatment Plant 9

Industry Electrolysis RO Brackish Water Treatment Plant 10Industry Electrolysis RO Brackish Water Treatment Plant 11

 

Contact Details
Vera

WhatsApp : +17391819659