Capacity: | 750lph | RO Frame: | SS Box |
---|---|---|---|
Rejection: | 98% | Recovery Rate: | 70%-85% |
Control: | Automatic | Pumps: | CNP, Grundfos |
Membrane Size: | 4040 | Membrane QTY: | 3pcs |
After-sales Service Provided: | Online Support,Video Technical Support,Field Installation,commissioning And Training,Free Spare Parts | Voltage: | 220V /380V/460V - 50Hz/60Hz,220V 50HZ 1P Customize Can Offer |
Ro Membrane: | Hydranautics,DOW / Vontron/ BNKO | Warranty: | 12 Month |
High Light: | XST Containerized Water Treatment Plant,750lph Containerized Water Treatment Plant,750lph Reverse Osmosis System |
750LPH Containerized Water Treatment Plant Reverse Osmosis System With BOX
Introduction of Containerized Water Treatment Plant
Reverse osmosis (RO) is a water purification process that uses a partially permeable membrane to remove ions, unwanted molecules and larger particles from drinking water. In reverse osmosis, an applied pressure is used to overcome osmotic pressure, a colligative property that is driven by chemical potential differences of the solvent, a thermodynamic parameter. Reverse osmosis can remove many types of dissolved and suspended chemical species as well as biological ones (principally bacteria) from water, and is used in both industrial processes and the production of potable water. The result is that the solute is retained on the pressurized side of the membrane and the pure solvent is allowed to pass to the other side. To be "selective", this membrane should not allow large molecules or ions through the pores (holes), but should allow smaller components of the solution (such as solvent molecules, i.e., water, H2O) to pass freely.
In the normal osmosis process, the solvent naturally moves from an area of low solute concentration (high water potential), through a membrane, to an area of high solute concentration (low water potential). The driving force for the movement of the solvent is the reduction in the free energy of the system when the difference in solvent concentration on either side of a membrane is reduced, generating osmotic pressure due to the solvent moving into the more concentrated solution. Applying an external pressure to reverse the natural flow of pure solvent, thus, is reverse osmosis.
Inlet Water Condition:
(For reference only,exact specification is subject to raw water and product):
1. Inlet water SDI(15 MINS):<5
2. Inlet water TURBIDITY:<1.0NTU
3. Inlet water Fe:<0.005ppm
4. Inlet water chlorine:(mg/l)<0.1
5. Inlet PH:2~11
6. Inlet water temperature:4~45℃
7. Desalination rate:95~99%
8. Outlet water PH:5~7
9. Output water meet the WHO drinking standard
Standard RO Parameter:
Model | Capability (Tons/Hr) |
Operation (MPa) |
Feed inlet (MM) |
Membrane Size(Inch) |
Membrane (Qty) |
Recovery | Power (KW) |
XSTRO-125L | 0.125 | 1.0-1.4 | DN20 | 40×21 | 1 | 30% | 1.1 |
XSTRO-250L | 0.25 | 1.0-1.4 | DN20 | 40×40 | 1 | 50% | 1.1 |
XSTRO-500L | 0.5 | 1.0-1.4 | DN20 | 40×40 | 2 | 50% | 1.5 |
XSTRO-750L | 0.75 | 1.0-1.4 | DN25 | 40×40 | 3 | 60% | 2.2 |
XSTRO-1000L | 1.0 | 1.0-1.4 | DN25 | 40×40 | 4 | 60% | 2.2 |
XSTRO-1500L | 1.5 | 1.0-1.4 | DN25 | 40×40 | 6 | 60% | 3.0 |
XSTRO-2000L | 2.0 | 1.0-1.4 | DN25 | 40×40 | 8 | 60% | 3.0 |
XSTRO-250LDP | 0.25 | 1.0-1.4 | DN20 | 40×40 | 3 | 50% | 2.6 |
XSTRO-500LDP | 0.5 | 1.0-1.4 | DN25 | 40×40 | 5 | 50% | 3.7 |
XSTRO-1000LDP | 1.0 | 1.0-1.4 | DN25 | 40×40 | 10 | 60% | 5.2 |
XSTRO-2000LDP | 2.0 | 1.0-1.4 | DN25 | 40×40 | 16 | 60% | 7.0 |
XSTRO-3 | 3.0 | 1.0-1.4 | DN32 | 40×40 | 12 | 65% | 4.0 |
XSTRO-6 | 6.0 | 1.0-1.4 | DN40 | 80×40 | 6 | 65% | 5.5 |
XSTRO-10 | 10.0 | 1.0-1.4 | DN50 | 80×40 | 10 | 75% | 11 |
XSTRO-15 | 15.0 | 1.0-1.4 | DN50 | 80×40 | 15 | 75% | 15 |
XSTRO-20 | 20.0 | 1.0-1.4 | DN65 | 80×40 | 20 | 75% |
18.5 |
1). With wheels, it can be moved to different demand places for use
2). Highly automatic.
3). No need the chemical regeneration, easy operation.
4). RO system choose the import USA DOW membrane.
5). Automatic switch on when low raw water level,and switch off when high pure water level.
6). RO membrane can backwash automatic and reduce the pollution.
7). Water shortage protection for high pump.
8). Low operation Cost and Long life span.
9). Easily control and Maintained.
10). Auto membrane flushing.
11). Environmental protection, Low power consumption.